Back To American Home Inspection Main Page
Plumbing And Drains
Plumbing may be defined as practice, materials, and
fixtures used in the installation, maintenance, and alteration of all piping,
fixtures, appliances, and appurtenances in connection with sanitary or storm
drainage facilities, the venting system, and the public or private water supply
systems. Plumbing does not include the trade of drilling water wells, installing
water softening equipment, or the business of manufacturing or selling plumbing
fixtures, appliances, equipment, or hardware. A plumbing system consists of
three separate parts: an adequate potable water supply system, a safe, adequate
drainage system and ample fixtures and equipment.
Background Factors 
The generalized inspection of a home is
concerned with a safe water supply system, an adequate drainage system, and
ample and proper fixtures and equipment. This explains features of a residential
plumbing system and the basic plumbing terms the inspector must know and
understand to identify properly housing code violations involving plumbing and
the more complicated defects that he will refer to the appropriate agencies.
Definitions
Air Chambers
Pressure absorbing devices that eliminate water
hammer. They should be installed as close as possible to the valves or faucet
and at the end of long runs of pipe.
Air Gap (Drainage System)
The unobstructed vertical distance through the free
atmosphere between the outlet of a water pipe and the flood level rim of the
receptacle into which it is discharging.
Air Gap (Water Distribution
System)
The unobstructed vertical distance through the free
atmosphere between the lowest opening from any pipe or faucet supplying water to
a tank, plumbing fixture, or other device and the flood level rim of the
receptacle.
Air Lock
An air lock is a bubble of air which restricts the
flow of water in a pipe.
Backflow
The flow of water or other
liquids, mixtures, or substances into the distributing pipes of a potable water
supply from any source or sources other than the intended source. Back siphonage
is one type of backflow.
Back Siphonage
The flowing back of used, contaminated, or polluted
water from a plumbing fixture or vessel into a potable water supply due to a
negative pressure in the pipe.
Branch
Any part of the piping system other than the main,
riser, or stack.
Branch Vent
A vent connecting one or more individual vents with
a vent stack.
Building Drain
The part of the lowest piping of a drainage system
that receives the discharge from soil, waste, or other drainage pipes inside the
walls of the building (house) and conveys it to the building sewer beginning 3
feet outside the building wall.
Cross Connection
Any physical connection or arrangement between two
otherwise separate piping systems, one of which contains potable water and the
other either water of unknown or questionable safety or steam, gas, or chemical
whereby there may be a flow from one system to the other, the direction of flow
depending on the pressure differential between the two systems. (See Backflow
and Back siphonage.)
Disposal Field
An area containing a series of one or more trenches
lined with coarse aggregate and conveying the effluent from the septic tank
through vitrified clay Pine or perforated, non-metallic pipe, laid in such a
manner that the flow will be distributed with reasonable uniformity into natural
soil.
Drain
Any pipe that carries waste water or water-borne
waste in a building (house) drainage system.
Flood Level Rim
The top edge of a receptacle from which water
overflows.
Flushometer Valve
A device that discharges a predetermined quantity
of water to fixtures for flushing purposes and is closed by direct water
pressures.
Flush Valve
A device located at the bottom of the tank for
flushing water closets and similar
fixtures.
Grease Trap
See
Interceptor.
Hot Water
Potable water that is heated to at least 120°F and
used for cooking, cleaning, washing dishes, and bathing.
Insanitary
Contrary to sanitary principles injurious to
health.
Interceptor
A device designed and installed so as to separate
and retain deleterious, hazardous, or undesirable matter from normal wastes and
permit normal sewage or liquid wastes to discharge into the drainage system by
gravity.
Leader
An exterior drainage pipe for conveying storm water
from roof or gutter drains to the building storm drain, combined building sewer,
or other means of disposal.
Main Vent
The principal artery of the venting system, to
which vent branches may be connected.
Main Sewer
See Public Sewer.
Pneumatic
The word pertains to devices making use of
compressed air as in pressure tanks boosted by
pumps.
Potable Water
Water having no impurities present in amounts
sufficient to cause disease or harmful physiological effects and conforming in
its bacteriological and chemical quality to the requirements of the Public
Health Service drinking water standards or meeting the regulations of the public
health authority having jurisdiction.
P & T (Pressure and Temperature) Relief
Valve
A safety valve installed on a hot water storage
tank to limit temperature and pressure of the
water.
P Trap
A trap with a vertical inlet and a horizontal
outlet.
Public Sewer
A common sewer directly controlled by public
authority.
Relief Vent
An auxiliary vent that permits additional
circulation of air in or between drainage and vent systems.
Septic Tank
A watertight receptacle that receives the discharge
of a building's sanitary drain system or part thereof and is designed and
constructed so as to separate solid from the liquid, digest organic matter
through a period of detention, and allow the liquids to discharge into the soil
outside of the tank through a system of open-joint or perforated piping, or
through a seepage pit.
Sewerage System
A sewerage system comprises all piping,
appurtenances, and treatment facilities used for the collection and disposal of
sewage, except plumbing inside and in connection with buildings served and the
building drain.
Soil Pipe
The pipe that directs the sewage of a house to the
receiving sewer, building drain, or building sewer.
Soil Stack
The vertical piping that terminates in a roof vent
and carries off the vapors of a plumbing system.
Stack Vent
An extension of a solid or waste stack above the
highest horizontal drain connected to the stack. Sometimes called a waste vent
or a soil vent.
Storm Sewer
A sewer used for conveying rain water, surface
water, condensate. cooling water, or similar liquid
waste.
Trap
A trap is a fitting or device that provides a
liquid seal to prevent the emission of sewer gases without materially affecting
the flow of sewage or waste water through
it.
Vacuum Breaker
A device to prevent backflow (back siphonage) by
means of an opening through which air may be drawn to relieve negative pressure
(vacuum).
Vent Stack
The vertical vent pipe installed to provide air
circulation to and from the drainage system and that extends through one or more
stories.
Water Hammer
The loud thump of water in a pipe when a valve or
faucet is suddenly closed.
Water Service Pipe
The pipe from the water main or other sources of
potable water supply to the water-distributing system of the building served.
Water Supply System
The water supply system consists of the water
service pipe, the water-distributing pipes, the necessary connecting pipes,
fittings, control valves, and all appurtenances in or adjacent to the building
or premises.
Wet Vent
A vent that receives the discharge of waste other
than from water closets.
Yoke Vent
A pipe connecting upward from a soil or waste stack
to a vent stack for the purpose of preventing pressure changes in the stacks.
Main Features of an Indoor Plumbing
System
The primary functions of the plumbing system
within the house are as follows:
- To bring an adequate and potable supply of hot and
cold water to the users of the dwelling.
- To drain all waste water and sewage discharged from these
fixtures into the public sewer, or private disposal system.
It is, therefore, very important that
the housing inspector familiarize himself fully with all elements of these
systems so that he may recognize inadequacies of the structure's plumbing as
well as other code violations.
Elements of a Plumbing
System
Water Service: The piping of a
house service line should be as short as possible. Elbows and bends should be
kept to a minimum since these reduce the pressure and therefore the supply of
water to fixtures in the house. The house service line should also be protected
from freezing. The burying of the line under 4 feet of soil is a commonly
accepted depth to prevent freezing. This depth varies, however, across the
country from north to south. The local or state plumbing code should be
consulted for the recommended depth in your area of the country.
The materials used for a house service may be copper, cast iron, steel or
wrought iron. The connections used should be compatible with the type of pipe
used.
- Corporation stop - The corporation stop is connected
to the water main. This connection is usually made of brass and can be connected
to the main by use of a special tool without shutting off the municipal supply.
The valve incorporated in the corporation stop permits the pressure to be
maintained in the main while the service to the building is completed.
- Curb stop - The curb stop is a
similar valve used to isolate the building from the main for repairs, nonpayment
of water bills, or flooded basements. Since the corporation stop is usually
under the street and would necessitate breaking the pavement to reach the valve,
the curb stop is used as the isolation valve.
- Curb stop box - The curb stop box
is an access box to the curb stop for opening and closing the valve. A
long-handled wrench is used to reach the valve.
- Meter stop -The meter stop is a
valve placed on the street side of the water meter to isolate the meter for
installation or maintenance. Many codes require a gate valve on the house side
of the meter to shut off water for house plumbing repairs. The curb and meter
stops are not to be used frequently and can be ruined in a short time if used
very frequently.
- Water meter - The water meter is
a device used to measure the amount of water used in the house. It is usually
the property of the city and is a very delicate instrument that should not be
abused. Since the electric system is usually
grounded to the water line, a grounding loop-device should be installed around
the meter. Many meters come with a yoke that maintains electrical continuity
even though the meter is removed.
Hot and Cold Water Main Lines: The hot and cold water
main lines are usually hung from the basement ceiling and are attached to the
water meter and hot-water tank on one side and the fixture supply risers on the
other. These pipes should be installed in a neat manner and should be supported
by pipe hangers or straps of sufficient strength and number to prevent sagging.
Hot and cold water lines should be approximately 6 inches apart unless the hot
water line is insulated. This is to insure that the cold water line does not
pick up heat from the hot water line. The supply mains should have a drain valve
or stop and waste valve in order to remove water from the system for repairs.
These valves should be on the low end of the line or on the end of each fixture
riser.
The fixture risers start at the
basement main and rise vertically to the fixtures on the upper floors. In a
one-family dwelling, riser branches will usually proceed from the main riser to
each fixture grouping. In any event the fixture risers should not depend on the
branch risers for support but should be supported with a pipe
bracket. Each fixture is then connected to the branch riser
by a separate line. The last fixture on a line is usually connected directly to
the branch riser.
Hot Water
Heaters: Hot water heaters are usually powered by electricity, fuel
oil, gas, or in rare cases, coal or wood. They consist of a space for heating
the water and a storage tank for providing hot water over a limited period of
time. All hot water heaters should be fitted with a temperature-pressure relief
valve no matter what fuel is used. This valve will operate when either the
temperature or the pressure becomes too high due to an interruption of the water
supply or a faulty thermostat.
Pipe Sizes: The size of
basement mains and risers depends on the number of fixtures supplied. However, a
3/4 inch pipe is usually the minimum size used. This allows for deposits on the
pipe due to hardness in the water and will usually give satisfactory volume and
pressure.
Drainage System
The water supply
brought into the house and used is discharged through the drainage system. This
system is either a sanitary drainage system carrying just interior waste water
or a combined system carrying interior waste and roof runoff.
Sanitary Drainage System: The
proper sizing of the sanitary drain or house drain depends on the number of
fixtures it serves. The usual minimum size is 6 inches in dial diameter. The
materials used are usually cast iron, vitrified clay, plastic, and in rare
cases, lead. For proper flow in the drain the pipe should be sized so that it
flows approximately one-half full. This ensures proper scouring action so that
the solids contained in the waste will not be deposited in the pipe.
- Sizing of house drain - The Uniform Plumbing Code
Committee has developed a method of sizing of house drains in terms of "fixture
units." One ''fixture unit" equals approximately 71 D2 gallons of water per
minute. This is the surge flow-rate of water discharged from a wash basin in 1
minute. All other fixtures have been related to this unit.
Sanitary Drain Sizes
- Grade of house drain - A house drain or building
sewer should be sloped toward the sewer to ensure scouring of the drain.
The usual pitch of a house or building sewer is 1
D4 inch fall in 1 foot of length.
- Fixture and branch drains - A branch drain is a waste pipe that
collects the waste from two or more fixtures and conveys it to the building or
house sewer. It is sized in the same way as the house sewer, taking into account
that all water closets must have a minimum 3-inch diameter drain, and only two
water closets may connect into one 3-inch drain.
All branch drains must join the house drain with a "Y" -type
fitting. The same is true for fixture drains joining branch drains. The "Y"
fitting is used to eliminate, as much as possible, the deposit of solids in or
near the connection. A build-up of these solids will cause a blockage in the
drain.
- Traps - A plumbing trap is a device used in a waste
system to prevent the passage of sewer gas into the structure and yet not hinder
the fixture's discharge to any great extent. All fixtures connected to a
household plumbing system should have a trap installed in the line.
The effect of sewer gases on the human
body are known; many are extremely harmful. Additionally, certain sewer gases
are explosive. A trap will prevent these gases from passing into the structure.
The depth of the seal in a trap is usually 2 inches. A deep seal trap has a
4-inch seal.
The purpose of a trap is to seal out sewer gases
from the structure. Since a plumbing system is subject to wide variations in
flow, and this flow originates in many different sections of the system, there
is a wide variation in pressures in the waste lines. These pressure differences
tend to destroy the water seal in the trap. To counteract this problem
mechanical traps were introduced. It has been found, however, that the corrosive
liquids flowing in the system corrode or jam these mechanical traps. It is for
this reason that most plumbing codes prohibit mechanical traps.
There are many manufacturers of traps, and all have
varied the design somewhat. The "P" trap is usually found in lavatories, sinks,
urinals, drinking fountains, showers, and other installations that do not
discharge a great deal of water.
Drum trap
The drum trap is another water seal-type trap. They
are usually used in the 4x5-inch or 4x8-inch sizes. These traps have a greater
sealing capacity than the "P" trap and pass large amounts of water quickly. Drum
traps are commonly connected to bathtubs, foot baths, sitz baths, and modified
shower baths.
Objectionable traps
The "S" 1 and the 3h "S" trap should not be us in
plumbing installations. They are almost impossible to ventilate properly, and
the 3h "S" trap forms a perfect siphon.
The bag trap, an extreme form of "S"
trap, is seldom found.
Any trap that depends on a moving part for its
effectiveness is usually inadequate and has been prohibited by the local
plumbing codes. These traps work, but their design usually results in their
being higher priced than the "P" or drum traps. It should be remembered that
traps are used only to prevent the escape of sewer gas into the structure. They
do not compensate for pressure variations. Only proper venting will eliminate
pressure problems.
Ventilation
A plumbing system is ventilated to prevent trap
seal loss, material deterioration. and flow retardation.
Trap
seal loss
The seal in a plumbing trap may be lost due to
siphonage (direct and indirect or momentum), back pressure, evaporation,
capillary attraction, or wind effect. The first two named are probably the most
common causes of loss. If a waste pipe is placed vertically after the fixture
trap, as in an "S" trap, the waste water continues to flow after the fixture is
emptied and clears the trap. This is caused by the pressure of air on the
fixture water's being greater than the pressure of air in the waste pipe. The
action of the water discharging into the waste pipe removes the air from that
pipe and thereby causes a negative pressure in the waste line. In the case of
indirect or momentum siphonage, the flow of water past the entrance to a fixture
drain in the waste pipe removes air from the fixture drain. This reduces the air
pressure in the fixture drain, and the entire assembly acts as an aspirator such
as the physician uses to spray an infected throat.
Back
pressure
The flow of water in a soil pipe varies according
to the fixtures being used. A lavatory gives a small flow and a water closet a
large flow. Small flows tend to cling to the sides of the pipe, but large ones
form a slug of waste as they drop. As this slug of water falls down the pipe the
air in front of it becomes pressurized. As the pressure builds it seeks an
escape point. This point is either a vent or a fixture outlet. If the vent is
plugged or there is no vent, the only escape for this air is the fixture outlet.
The air pressure forces the trap seal up the pipe into the fixture. If the
pressure is great enough the seal is blown out of the fixture entirely. Figures
6-17 and 6-18 illustrate this type of problem.
Vent
sizing
Vent pipe installation is similar to that of soil
and waste pipe. The same fixture unit criteria are used. Vent pipes of less than
11 D4 inches in diameter should not be used. Vents smaller than this diameter
tend to clog and do not perform their function.
- Individual fixture ventilation - This type of ventilation is generally used for sinks, lavatories,
drinking fountains, and so forth
- Unit venting - The unit venting
system is commonly used in apartment buildings. This type of system saves a
great deal of money and space when fixtures are placed back to back in separate
apartments.
- Wet venting - Wet venting of a
plumbing system is common in household bathroom fixture grouping. It is exactly
what the name implies: the vent pipe is used as a waste
line.
Total drainage system
Up to now we have talked about the drain, soil
waste, and vent systems of a plumbing system separately. For a working system,
however, they must all be connected.
Back To American Home Inspection Main Page